• DocumentCode
    2896462
  • Title

    A simulation model for a same day care facility at a university hospital

  • Author

    Iskander, Wafik H. ; Carter, D. Mark

  • Author_Institution
    Dept. of Ind. Eng., West Virginia Univ., Morgantown, WV, USA
  • fYear
    1991
  • fDate
    8-11 Dec 1991
  • Firstpage
    846
  • Lastpage
    853
  • Abstract
    A simulation model was developed to evaluate the adequacy of the ambulatory care center space planned for the same-day care center at West Virginia University Medical Center. After thorough testing, the model was implemented, and results were obtained for different scenarios and modes of operation. Based on the results produced, officials at the hospital altered their original design and moved some of the services to the main hospital. After the study was performed, construction was completed for the outpatient care facility, and the same-day care unit was moved into it under the split service arrangement recommended from the analysis of the simulation results. After several months of operation, real-life results confirmed those predicted by the model
  • Keywords
    digital simulation; medical administrative data processing; ambulatory care center space; outpatient care facility; same day care facility; simulation model; university hospital; Construction industry; Costs; Endoscopes; Hospitals; Industrial engineering; Medical services; Medical simulation; Surgery; System performance; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Simulation Conference, 1991. Proceedings., Winter
  • Conference_Location
    Phoenix, AZ
  • Print_ISBN
    0-7803-0181-1
  • Type

    conf

  • DOI
    10.1109/WSC.1991.185694
  • Filename
    185694