Abstract :
The visible sub-20 fs pulses of a noncollinear optical parametric amplifier (NOPA) are shaped with a LCD mask in a 4f setup and converted to the UV by sum frequency mixing with stretched NIR pulses from a Ti:sapphire amplifier system. To characterize the temporal shape of the resulting UV pulses, cross correlations are measured by difference frequency generation with 20 fs pulses at 700 nm generated by a second NOPA. The achieved pulse lengths are well below vibrational periods of molecular skeletal motions while the intervals in such a pulse train can be adopted to a vibrational frequency.
Keywords :
liquid crystal displays; multiwave mixing; optical frequency conversion; optical parametric amplifiers; optical pulse shaping; sapphire; titanium; 20 fs; 4f setup; 700 nm; Al2O3:Ti; LCD mask; NIR pulses stretching; Ti:sapphire amplifier system; UV pulse; cross correlation; difference frequency generation; molecular skeletal motion; noncollinear OPA; noncollinear optical parametric amplifier; pulse length; pulse train; sum frequency mixing; temporal shape; tunable pulse shaping; vibrational frequency; vibrational period; Character generation; Frequency; Optical amplifiers; Optical pulse generation; Optical pulse shaping; Pulse amplifiers; Pulse measurements; Pulse shaping methods; Semiconductor optical amplifiers; Shape measurement;
Conference_Titel :
Lasers and Electro-Optics Europe, 2005. CLEO/Europe. 2005 Conference on
Print_ISBN :
0-7803-8974-3
DOI :
10.1109/CLEOE.2005.1568121