DocumentCode
2899738
Title
Measurement for the kanthal alloy used for collinear load and the s-band load design
Author
He, Xiaodong ; Wu, Cong-Feng ; Dong, Sai ; Pei, Yuanji
Author_Institution
USTC, Hefei
fYear
2007
fDate
25-29 June 2007
Firstpage
2146
Lastpage
2148
Abstract
We have developed the method to determine the permeability and the electrical conductivity of the Kanthal alloy available. The alloy is coated inside the walls of disk-loaded cavities, which is used for the collinear load. The collinear load absorbs the remaining RF power over the last cells of the section while still accelerating the beam. Based on the experimental results of permeability and the calculated value of the conductivity, the computation study of the collinear load has been made by Microwave Studio. The attenuation in the collinear load is 16.02 dB.
Keywords
accelerator RF systems; accelerator cavities; aluminium alloys; beam handling techniques; chromium alloys; electrical conductivity; electron accelerators; iron alloys; magnetic permeability; FeCrAlJk; Kanthal alloy; Microwave Studio; RF power; S-band load design; accelerating beam; computation study; disk-cavities; electrical conductivity; electron accelerators; magnetic permeability; Coaxial cables; Conducting materials; Conductivity; Electric resistance; Magnetic materials; Metal foam; Permeability; Power cables; Radio frequency; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2007. PAC. IEEE
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0916-7
Type
conf
DOI
10.1109/PAC.2007.4441178
Filename
4441178
Link To Document