• DocumentCode
    2901525
  • Title

    An RF waveguide distribution system for the ILC test accelerator at Fermilab´s NML

  • Author

    Nantista, Christopher ; Adolphsen, Chris ; Bowden, Gordon ; Swent, Richard ; McKee, Bobby

  • Author_Institution
    SLAC, Menlo Park
  • fYear
    2007
  • fDate
    25-29 June 2007
  • Firstpage
    2442
  • Lastpage
    2444
  • Abstract
    An ILC R&D facility is being constructed in the NML building at Fermilab which, in addition to an injector and beam dump with spectrometer, will contain up to three cryomodules of ILC-type superconducting 9-cell cavities. This linac will be powered by a single klystron. As part of SLAC´s contribution to this project, we will provide a distribution network in WR650 waveguide to the various cavity couplers. In addition to commercial waveguide components and circulators and loads, this system will include adjustable tap-offs, and customized hybrids. In one configuration, the circulators will be removed to test pair-wise cancellation of cavity reflections through hybrids. The system will be pressurized with nitrogen to 3 bar absolute to avoid the need for SF6. The full distribution system for the first cryomodule will be delivered and installed later this year. We describe the design of the system and completed RF testing.
  • Keywords
    accelerator RF systems; linear accelerators; microwave circulators; superconducting devices; ILC test accelerator; ILC-type superconducting 9-cell cavities; International Linear Collider; RF waveguide distribution system; cavity reflections; Buildings; Circulators; Couplers; Klystrons; Life estimation; Linear particle accelerator; Radio frequency; Spectroscopy; System testing; Waveguide components;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2007. PAC. IEEE
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0916-7
  • Type

    conf

  • DOI
    10.1109/PAC.2007.4441277
  • Filename
    4441277