DocumentCode :
2902865
Title :
1.3 GHz, 10 MWp long pulse multibeam klystrons: A long heritage and proven reliability
Author :
Marchesin, R. ; Beunas, A. ; Legrand, F. ; Thouvenin, P. ; Caplot, M. ; Boghossian, E.
Author_Institution :
Thales Electron Devices, Vélizy-Villacoublay, France
fYear :
2011
fDate :
21-24 Feb. 2011
Firstpage :
315
Lastpage :
316
Abstract :
Thales Electron Devices has been developing and manufacturing 10MW L-band vertical Multi Beam Klystrons (TH1801) for TTF, FLASH and PITZ machines at DESY for more than 10 years. At this point, 8 tubes have been installed at DESY with more than 80 000 hours of cumulated RF operation. All over these years, THALES has been collecting data on MBK tubes behavior which permitted to improve continuously the design margins and reliability. In order to allow horizontal installation in the XFEL tunnel, a horizontal version (TH1802) was fabricated, tested and qualified. The key performance of this tube is its high stability under all various operating conditions.
Keywords :
electron beams; klystrons; reliability; FLASH machine; L-band vertical multibeam klystron; MBK tube behavior; PITZ machine; RF operation; TTF machine; Thales electron device; XFEL tunnel; frequency 1.3 GHz; high stability; long pulse multibeam klystron; reliability; Electric fields; Klystrons; L-band; Radio frequency; Reliability; X-ray lasers; XFEL; multi-beam klystron; reliability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Vacuum Electronics Conference (IVEC), 2011 IEEE International
Conference_Location :
Bangalore
Print_ISBN :
978-1-4244-8662-5
Type :
conf
DOI :
10.1109/IVEC.2011.5747002
Filename :
5747002
Link To Document :
بازگشت