Title :
Remote monitoring of body caloric expenditure using wireless devices
Author :
Rotariu, Cristian ; Pasarica, Alexandru ; Costin, Hariton ; Arotaritei, Dragos ; Mancas, Malina
Author_Institution :
Dept. of Biomed. Sci., “Grigore T. Popa” Univ. of Med. & Pharmacy, Iasi, Romania
Abstract :
The purpose of this paper was to design and develop a reliable remote monitoring system that allows health care professionals to monitor the daily calories expenditure of obese subjects. The system was implemented by using the Z430-Chronos wireless development kit and BM-CS5 wireless chest strap. These devices were used to acquire and wirelessly transfer to a PC the measured caloric expenditure for the monitored subject. The calories expenditure are computed based on heart rate, provided by the chest strap, and accelerometer data acquired with CMA3000-D01 tri-axial accelerometer sensor from eZ430-Chronos watch. A graphic user interface was designed and implemented by using the LabWindows/CVI environment in order to display the temporal waveform of the daily caloric balance for the selected subject. The implemented system was tested on a group of seven obese subjects during a 90 days study. They were required to do daily physical exercises, being monitored by the described system, followed by the estimation of calories expenditure used in determining their daily caloric balance computed as difference between calories intake and the sum of calories expenditure and basal metabolic rate. The evolution of the subjects was quantified by using the biochemical parameters determined at the beginning and at the end of the days study. The difference of the biochemical results for each subject showed improvements by the lowering of high risk parameters: HDL-cholesterol, glucose, insulin.
Keywords :
accelerometers; biochemistry; biomedical equipment; data acquisition; gait analysis; graphical user interfaces; health care; medical computing; patient monitoring; sugar; wireless sensor networks; BM-CS5 wireless chest strap; CMA3000-D01 tri-axial accelerometer sensor; HDL-cholesterol; LabWindows-CVI environment; Z430-Chronos wireless development kit; accelerometer data acquisition; basal metabolic rate; biochemical parameters; body caloric expenditure; caloric expenditure; daily caloric balance; daily physical exercises; eZ430-Chronos watch; glucose; graphic user interface; health care; heart rate; insulin; remote monitoring system; wireless devices; Biomedical monitoring; Heart rate; Insulin; Remote monitoring; Wireless communication; Wireless sensor networks; caloric expenditure; remote monitoring; wireless devices;
Conference_Titel :
Advanced Topics in Electrical Engineering (ATEE), 2015 9th International Symposium on
Conference_Location :
Bucharest
DOI :
10.1109/ATEE.2015.7133822