DocumentCode
2905324
Title
Evaluation of the Thermal Resistance of CSOP24 Ceramic Package
Author
Peng, Xiao ; Wang, Shuidi ; Jia, Songliang ; Cai, Jian ; Huang, Qiang ; Ding, Rongzhen
Author_Institution
Tsinghua Univ., Beijing
fYear
2007
fDate
14-17 Aug. 2007
Firstpage
1
Lastpage
4
Abstract
On the basis of MIL STD 883 method 1012 and SEMI standard G30-88 and G32-86. purely electrical approaches were implemented to measure the thermal resistance of CSOP24 package. Firstly the temperature sensitive parameter (TSP) was measured and calibrated in a temperature controlled fluid trough. Then proper test conditions including measurement current (IM) and test power PHmiddot were chosen according to experiments. Thermal resistance measurements were carried out in the two conditions: radiator with big heat sink which keeps the case temperature Tc at 60 degC. and temperature controlled fluid trough. In addition, two kinds of thermal test chips with different size (1.91times1.91mm and 3.92times3.92mm) were used to test the influence of the chip size. Experimental result was provided. Moreover, the thermal resistance of the CSOP24 package was simulated by utilizing Fluent software.
Keywords
ceramic packaging; heat sinks; thermal resistance measurement; CSOP24 ceramic package; Fluent software; electrical approaches; heat sink; temperature sensitive parameter; thermal resistance measurements; Ceramics; Electric resistance; Electric variables measurement; Electrical resistance measurement; Measurement standards; Packaging; Temperature control; Temperature sensors; Testing; Thermal resistance;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Packaging Technology, 2007. ICEPT 2007. 8th International Conference on
Conference_Location
Shanghai
Print_ISBN
978-1-4244-1392-8
Electronic_ISBN
978-1-4244-1392-8
Type
conf
DOI
10.1109/ICEPT.2007.4441523
Filename
4441523
Link To Document