Title :
The effect of corona wire heating and geometry on ozone generation in a negative ion air cleaner
Author :
Linmao, Liu ; Jingfu, Guo ; Jie, Li ; Lianxi, Sheng
Author_Institution :
Dept. of Environ. Sci., Northeast Normal Univ., Changchun, China
Abstract :
The effect of corona wire surface temperature and geometry on the ozone generation and negative ion emission in a negative ion air cleaner is studied experimentally. The results show that corona wire heating can suppress the ozone generation; however, this increases the corona current. A trade-off effect of corona wire surface temperature and corona current exists; the specific value of ozone concentration against negative ion current is affected by the wire surface temperature and geometry and decreases with an increase in wire surface temperature, the size of grounded screen holes and electrodes space and a reduction in wire diameter
Keywords :
air pollution control; corona; electrostatic devices; negative ions; ozone; thermal analysis; wires (electric); corona current; corona wire geometry; corona wire heating; corona wire surface temperature; electrodes space; grounded screen holes; negative ion air cleaner; negative ion emission; ozone generation; wire diameter; Air cleaners; Artificial intelligence; Corona; Electrodes; Geometry; Heating; Surface discharges; Temperature; Testing; Wire;
Conference_Titel :
Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE
Conference_Location :
New Orleans, LA
Print_ISBN :
0-7803-4067-1
DOI :
10.1109/IAS.1997.626290