• DocumentCode
    2906749
  • Title

    The effect of corona wire heating and geometry on ozone generation in a negative ion air cleaner

  • Author

    Linmao, Liu ; Jingfu, Guo ; Jie, Li ; Lianxi, Sheng

  • Author_Institution
    Dept. of Environ. Sci., Northeast Normal Univ., Changchun, China
  • Volume
    3
  • fYear
    1997
  • fDate
    5-9 Oct 1997
  • Firstpage
    1744
  • Abstract
    The effect of corona wire surface temperature and geometry on the ozone generation and negative ion emission in a negative ion air cleaner is studied experimentally. The results show that corona wire heating can suppress the ozone generation; however, this increases the corona current. A trade-off effect of corona wire surface temperature and corona current exists; the specific value of ozone concentration against negative ion current is affected by the wire surface temperature and geometry and decreases with an increase in wire surface temperature, the size of grounded screen holes and electrodes space and a reduction in wire diameter
  • Keywords
    air pollution control; corona; electrostatic devices; negative ions; ozone; thermal analysis; wires (electric); corona current; corona wire geometry; corona wire heating; corona wire surface temperature; electrodes space; grounded screen holes; negative ion air cleaner; negative ion emission; ozone generation; wire diameter; Air cleaners; Artificial intelligence; Corona; Electrodes; Geometry; Heating; Surface discharges; Temperature; Testing; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE
  • Conference_Location
    New Orleans, LA
  • ISSN
    0197-2618
  • Print_ISBN
    0-7803-4067-1
  • Type

    conf

  • DOI
    10.1109/IAS.1997.626290
  • Filename
    626290