Abstract :
Induction machines usually have a reduced efficiency when supplied with non linear currents. Most of the induction machines are not used at nominal loading, but at a 60% loading rate. In the paper it will be shown that derating factors for induction motors fed with nonlinear currents, like the NEMA MG1 or the IEC 60034-17, are correct for nominal loading. At lower loading these derating factors can underestimate the losses. The measurements shown in this paper indicate that for low loading percentages, the phase angles of the harmonics have a significant influence on the peak induction and therefore the saturation level of the induction machine. For low loading rates the constant losses, including the magnetization losses, are the dominant losses. For a correct estimation of the losses for motors working at low loading conditions, the phase of the harmonics has to be taken in account.
Keywords :
asynchronous machines; induction motors; losses; magnetisation; power engineering computing; power system harmonics; constant losses; derating factors; direct online induction machines; induction motors; magnetization losses; voltage harmonics; Equations; Harmonic analysis; Induction motors; Loading; Magnetic losses; Mathematical model; efficiency; harmonics; induction machine; losses; magnetizing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
Conference_Location :
Niagara Falls, ON
Print_ISBN :
978-1-4577-0060-6
Type :
conf
DOI :
10.1109/IEMDC.2011.5994745
Filename :
5994745
Link To Document :
بازگشت