DocumentCode
2909967
Title
Validation of new Gibbs priors for Bayesian tomographic reconstruction using physically acquired data
Author
Lee, S.J. ; Choi, Y. ; Gindi, G.
Author_Institution
Dept. of Electron. Eng., Paichai Univ., Taejon, South Korea
Volume
3
fYear
1998
fDate
1998
Firstpage
1589
Abstract
The variety of Bayesian MAP approaches to tomography proposed in recent years can both stabilize reconstructions and lead to improved bias and variance. In the authors´ previous work (see S.J. Lee et al., IEEE Trans. Med. Imaging, vol. MI-14, no. 4, p. 669-80, 1995; S.J. Lee et al., IEEE Trans. Nucl. Sci., vol. NS-44, no. 3, p. 1381-7, 1997), they showed that the thin-plate (TP) prior, which is less sensitive to variations in first spatial derivatives than the conventional membrane (MM) prior, yields improved reconstructions in the sense of low bias. In spite of the several advantages of such quadratic smoothing priors, they are still less than ideal due to their limitations in edge preservation. Here, the authors use a convex-nonquadratic potential function, which provides a degree of edge preservation. As in the case of quadratic priors, a class of two-dimensional smoothing splines with first and second partial derivatives are applied to the new potential function. In order to reduce difficulties such as oversmoothing for MM and edge overshooting for TP, the authors also generalize the prior energy definition to that of a linear combination of MM and TP using a control parameter, and observe its transition between the two extreme cases. To observe the efficacies of their new priors, the authors use physically acquired PET emission data. They also test these priors in a transmission setting with physically acquired transmission data. The authors´ results indicate significant improvements in the quality of both emission and transmission images using their new priors
Keywords
Bayes methods; image reconstruction; medical image processing; positron emission tomography; splines (mathematics); Bayesian tomographic reconstruction; Gibbs priors validation; PET emission data; bias; control parameter; convex-nonquadratic potential function; edge overshooting; medical diagnostic imaging; nuclear medicine; physically acquired data; prior energy definition; quadratic smoothing priors; quality improvements; reconstructions stabilization; transmission images; two-dimensional smoothing splines; variance; Attenuation; Bayesian methods; Biomedical engineering; Biomembranes; Data engineering; Image reconstruction; Nuclear electronics; Nuclear medicine; Smoothing methods; Tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location
Toronto, Ont.
ISSN
1082-3654
Print_ISBN
0-7803-5021-9
Type
conf
DOI
10.1109/NSSMIC.1998.773846
Filename
773846
Link To Document