DocumentCode :
2910094
Title :
Fault detection, isolation and reconfiguration of three-phase AC drive with current sensor fault
Author :
Meinguet, Fabien ; Gyselinck, Johan
Author_Institution :
BEAMS Dept., Univ. Libre de Bruxelles (ULB), Brussels, Belgium
fYear :
2011
fDate :
15-18 May 2011
Firstpage :
200
Lastpage :
205
Abstract :
This paper deals with an on-line fault detection and isolation method for three-phase AC drives. Small magnitude fault is considered as well as complete current sensor outage. A way to deal with intermittent fault is also provided. The method is based on hardware redundancy with additional current sensors. This approach allows the fault isolation to be performed on the whole speed range including zero speed. It is inherently insensitive to the drive parameter uncertainties and variations. Moreover, the monitoring is executed while the machine is driven with a closed-loop controller and the full dynamic performances are continuously available. A decision system based on the “CUSUM” algorithm is described, which manages the post-fault operation by taking advantage of the system redundancy.
Keywords :
AC motor drives; electric sensing devices; fault diagnosis; redundancy; CUSUM algorithm; closed loop controller; current sensor fault; hardware redundancy; isolation method; magnitude fault; online fault detection; three-phase AC drive; Additives; Circuit faults; Current measurement; Fault detection; Noise measurement; Redundancy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
Conference_Location :
Niagara Falls, ON
Print_ISBN :
978-1-4577-0060-6
Type :
conf
DOI :
10.1109/IEMDC.2011.5994846
Filename :
5994846