DocumentCode :
2910149
Title :
CT image reconstruction from fan-parallel projection data
Author :
Besson, Guy M.
Author_Institution :
Appl. Sci. Lab., Gen. Electr. Co., Milwaukee, WI, USA
Volume :
3
fYear :
1998
fDate :
1998
Firstpage :
1644
Abstract :
Third generation fan-beam CT scanners acquire data one entire projection at a time. The associated filtered-backprojection algorithm requires a computationally expensive pixel-dependent weight factor in the backprojector. Methods of simplifying the reconstruction include rebinning the fan-beam data to parallel projections. The rebinning can be separated into two steps: azimuthal interpolation, leading to the fan-parallel geometry, where data are unevenly spaced on radial lines through the origin of Radon space, and a subsequent axial interpolation to parallel data. As under appropriate view and projection sampling conditions, the azimuthal interpolation can be replaced by either data re-sorting or projection channel-dependent delays, this paper investigates an Arcsin algorithm to reconstruct an image directly from the fan-parallel data. Although it is shown that the algorithm cannot be exact, a natural approximation is described. The pre-, post-convolution weights, and the reconstruction filter, are derived analytically. Imaging results demonstrate that direct fan-parallel reconstruction image quality matches fully that of parallel reconstruction. The fan-parallel reconstruction method eliminates the resolution-compromising axial interpolation and the costly pixel-dependent backprojection weight. Further, an Arcsin detector design is proposed for direct parallel reconstruction from fan-beam data
Keywords :
computerised tomography; image reconstruction; interpolation; medical image processing; Arcsin algorithm; Arcsin detector design; CT image reconstruction; azimuthal interpolation; computationally expensive pixel-dependent weight factor; costly pixel-dependent backprojection weight; data re-sorting; direct parallel reconstruction; fan-parallel geometry; fan-parallel projection data; medical diagnostic imaging; reconstruction simplification; resolution-compromising axial interpolation; third generation fan-beam CT scanners; Approximation algorithms; Computed tomography; Delay; Filters; Geometry; Image quality; Image reconstruction; Image sampling; Interpolation; Reconstruction algorithms;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location :
Toronto, Ont.
ISSN :
1082-3654
Print_ISBN :
0-7803-5021-9
Type :
conf
DOI :
10.1109/NSSMIC.1998.773856
Filename :
773856
Link To Document :