Abstract :
Reports on an iterative approach to reconstruct the activity f(x) directly from the emission sinogram data without additional transmission measurements. The proposed algorithm is based on iterative methods for solving linear operator equations. When an operator F is the sum of a linear and a bilinear operator, a modified iteration sequence can be defined. Using a Taylor series about a fixed approximate distribution μ0, the attenuated Radon transform can be well approximated as the sum of a linear operator in f and a bilinear operator in f and μ. The algorithm alternates between updates of f and updates of μ. Test computations for generated and real data show that the authors´ reconstructions achieve the same quality as reconstructions with known attenuation distribution
Keywords :
gamma-ray absorption; iterative methods; medical image processing; optimisation; single photon emission computed tomography; SPECT imaging; Taylor series; attenuation distribution; bilinear functions optimizations; bilinear operator; emission sinogram data; linear operator; medical diagnostic imaging; nuclear medicine; reconstruction quality; transmission measurements; unknown spatially-varying attenuation distribution; Attenuation measurement; Cities and towns; Drives; Equations; Image reconstruction; Iterative algorithms; Iterative methods; Radiology; Taylor series; Transforms;
Conference_Titel :
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location :
Toronto, Ont.
Print_ISBN :
0-7803-5021-9
DOI :
10.1109/NSSMIC.1998.773865