Image-space 3D scatter correction following list mode acquisition with a large-area positron camera
Author
Ott, R.J. ; Erlandsson, K. ; Flower, M.A. ; Reader, A.J.
Author_Institution
Phys. Dept., R. Marsden Hosp., Sutton, UK
Volume
3
fYear
1998
fDate
1998
Firstpage
1806
Abstract
Positron volume images will be produced by the new large-area positron camera PETRRA directly from list mode data acquisition. The present method of image reconstruction is based on the backprojection then filter algorithm and no projection data are produced. A 2D method of correcting images in back-projection space has been developed using measurements made with the existing MUP-PET camera. A relationship between the attenuation and scatter fractions has been derived, for a limited axial field-of-view, for a range of cylindrical and elliptical phantoms. Image-space scatter distributions produced using this relationship are converted to backprojection-space by convolution with an experimentally-derived scatter response function (SRF). These scatter distributions are subtracted from the acquired back-projected image using the integrated scatter fraction for normalization. The resulting data are corrected using a multiplicative backprojection space attenuation matrix and deconvolved with an in-air response function. The method has been applied to a Monte Carlo simulated phantom, an experimental phantom and a patient study. The predicted scatter distribution agrees with the simulation to ~±10% and the correction method improves image contrast for all three data sets studied. However the use of a spatially invariant SRF leads to over-subtraction of scatter in the center of the phantom. In order for the method to be extended to PETRRA using the whole axial extent (40 cm) of the camera, simulations have been used to generate scatter-attenuation relationships for several phantoms over the whole axial FoV. The scatter response function is fitted to a Gaussian with the center displaced from the point of emission. Improved linearity and contrast were obtained with simulated phantoms. The method could be applied to any large-area positron camera acquiring data in list mode
Keywords
Monte Carlo methods; data acquisition; gamma-ray scattering; image reconstruction; medical image processing; positron emission tomography; 2D image correction method; 40 cm; Gaussian; Monte Carlo simulated phantom; backprojection then filter algorithm; contrast; cylindrical and elliptical phantoms; elliptical phantoms; experimentally-derived scatter response function; in-air response function; integrated scatter fraction; large-area positron camera; limited axial field-of-view; linearity; medical diagnostic imaging; multiplicative backprojection space attenuation matrix; normalization; nuclear medicine; positron volume imaging; scatter distributions; simulated phantoms; Attenuation; Cameras; Data acquisition; Extraterrestrial measurements; Filters; Image converters; Image reconstruction; Imaging phantoms; Positrons; Scattering;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location
Toronto, Ont.
ISSN
1082-3654
Print_ISBN
0-7803-5021-9
Type
conf
DOI
10.1109/NSSMIC.1998.773888
Filename
773888
Link To Document