• DocumentCode
    2910837
  • Title

    fMRI artifacts reduction using Bayesian image processing

  • Author

    Kim, T. ; Al-Dayeh, L. ; Singh, M.

  • Author_Institution
    Depts. of Radiol. & Biomed. Eng., Univ. of Southern California, Los Angeles, CA, USA
  • Volume
    3
  • fYear
    1998
  • fDate
    1998
  • Firstpage
    1868
  • Abstract
    Functional MRI is known to be prone to artifacts caused by spatio-temporally varying structural noise components such as gross head motion, CSF pulsation, physiological fluctuation, and magnetic susceptibility changes. The presence of these artifacts can cause negative and positive false activation and obscure true activated pixels. Thus the reliability of the functional images can be diminished. The application of image registration or noise filtering can reduce artifacts related to motion and physiological pulsation, but cannot correct the locally differing spatial variations in T2* signal loss and the image distortions due to off-resonance effects. In our work, Bayesian image processing is applied to reduce noise and artifacts and to enhance true activity detection. The results indicate that Bayesian processing is effective in reducing fMRI noise and artifacts and in improving true activity detection by enhancing the connectivity of the activated pixels
  • Keywords
    Bayes methods; biomedical MRI; brain; image reconstruction; image registration; image sequences; maximum likelihood estimation; medical image processing; motion compensation; time series; Bayesian image processing; CSF pulsation; Gibbs priors; MAP estimates; T2* signal loss; artifacts reduction; brain activity; functional MRI; gross head motion; image distortions; image registration; image sequences; locally differing spatial variations; magnetic susceptibility changes; negative false activation; obscure true activated pixels; off-resonance effects; physiological fluctuation; positive false activation; prior knowledge; spatio-temporally varying structural noise; time series; Bayesian methods; Fluctuations; Image processing; Image registration; Magnetic heads; Magnetic noise; Magnetic resonance imaging; Magnetic separation; Magnetic susceptibility; Noise reduction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
  • Conference_Location
    Toronto, Ont.
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-5021-9
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1998.773900
  • Filename
    773900