DocumentCode
2911242
Title
New iterative algorithm for the SPECT diagnostics
Author
Likhachov, A.V. ; Pickalov, V.V.
Author_Institution
Inst. of Theor. & Appl. Mech., Acad. of Sci., Novosibirsk, Russia
Volume
3
fYear
1998
fDate
1998
Firstpage
1992
Abstract
An algorithm for three-dimensional SPECT diagnostics is developed. A step in the SPECT method is a reconstruction of spatial local emission coefficients distribution inside a patient´s body. A tissue absorption correction results in a more complicated problem compared with traditional X-ray or NMR tomography. The suggested algorithm allows the reconstruction of an unknown emission distribution when an absorption assumed to be an arbitrary function of spatial coordinates is known
Keywords
image reconstruction; iterative methods; medical image processing; single photon emission computed tomography; 3D SPECT diagnostics; arbitrary function of spatial coordinates; attenuation correction; iterative algorithm; iterative scheme; numerical simulation; projection scheme; spatial local emission coefficients distribution; tissue absorption correction; unknown emission distribution reconstruction; Electromagnetic wave absorption; Equations; Geometry; Image reconstruction; Iterative algorithms; Nuclear magnetic resonance; Numerical simulation; Q measurement; Radiation detectors; Single photon emission computed tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location
Toronto, Ont.
ISSN
1082-3654
Print_ISBN
0-7803-5021-9
Type
conf
DOI
10.1109/NSSMIC.1998.773924
Filename
773924
Link To Document