DocumentCode
2911716
Title
Experimental study of the effect of positive sequence voltage on the derating of induction motors under voltage unbalance
Author
Quispe, E.C. ; López-Fernández, X.M. ; Mendes, A.M.S. ; Cardoso, A. J Marques ; Palacios, J.A.
fYear
2011
fDate
15-18 May 2011
Firstpage
908
Lastpage
912
Abstract
This paper presents the results of an experimental study on derating of an induction motor under different voltage unbalanced conditions and its comparison with the NEMA standard MG1 voltage unbalance derating graph. During the derating tests the 4 kW squirrel cage induction motor temperature rise was kept constant at the rated value and the windings temperature was measured on-line by means of an accurate digital thermal monitoring system with nine thermocouples positioned in both stator and rotor circuits. The obtained results show that the positive sequence voltage plays an important role in the derating performance of the induction motor under unbalanced conditions, and that the unbalance voltage indices currently used do not allow for accurately measuring this influence.
Keywords
induction motors; thermocouples; digital thermal monitoring system; induction motors; positive sequence voltage; squirrel cage induction motor temperature rise; thermocouples; voltage unbalance; windings temperature; Heating; IEC standards; Induction motors; Monitoring; Rotors; Temperature measurement; Voltage measurement; Derating; NEMA MG1; heating test; induction motor; positive sequence voltage; thermal monitoring system; voltage unbalance;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
Conference_Location
Niagara Falls, ON
Print_ISBN
978-1-4577-0060-6
Type
conf
DOI
10.1109/IEMDC.2011.5994936
Filename
5994936