• DocumentCode
    2911716
  • Title

    Experimental study of the effect of positive sequence voltage on the derating of induction motors under voltage unbalance

  • Author

    Quispe, E.C. ; López-Fernández, X.M. ; Mendes, A.M.S. ; Cardoso, A. J Marques ; Palacios, J.A.

  • fYear
    2011
  • fDate
    15-18 May 2011
  • Firstpage
    908
  • Lastpage
    912
  • Abstract
    This paper presents the results of an experimental study on derating of an induction motor under different voltage unbalanced conditions and its comparison with the NEMA standard MG1 voltage unbalance derating graph. During the derating tests the 4 kW squirrel cage induction motor temperature rise was kept constant at the rated value and the windings temperature was measured on-line by means of an accurate digital thermal monitoring system with nine thermocouples positioned in both stator and rotor circuits. The obtained results show that the positive sequence voltage plays an important role in the derating performance of the induction motor under unbalanced conditions, and that the unbalance voltage indices currently used do not allow for accurately measuring this influence.
  • Keywords
    induction motors; thermocouples; digital thermal monitoring system; induction motors; positive sequence voltage; squirrel cage induction motor temperature rise; thermocouples; voltage unbalance; windings temperature; Heating; IEC standards; Induction motors; Monitoring; Rotors; Temperature measurement; Voltage measurement; Derating; NEMA MG1; heating test; induction motor; positive sequence voltage; thermal monitoring system; voltage unbalance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines & Drives Conference (IEMDC), 2011 IEEE International
  • Conference_Location
    Niagara Falls, ON
  • Print_ISBN
    978-1-4577-0060-6
  • Type

    conf

  • DOI
    10.1109/IEMDC.2011.5994936
  • Filename
    5994936