DocumentCode
2912970
Title
4-axis electromagnetic microgripper
Author
Menciassi, Arianna ; Hannaford, Blake ; Carrozza, Maria Chiara ; Dario, Paolo
Author_Institution
Scuola Superiore Sant´´Anna, MiTech Lab., Pisa, Italy
Volume
4
fYear
1999
fDate
1999
Firstpage
2899
Abstract
This paper describes a novel 4-axis microgripping system consisting of two fingers, each driven by a 2-axis moving coil actuator taken from a CD-lens assembly. These electromagnetic actuators are small, very linear, virtually frictionless and low cost. We measured the electrical actuator parameters and characterized the actuator performance in terms of displacement vs. current, force vs. current and resonant frequency. Experimental results indicate that the proposed microgripping system can be an attractive solution to the problem of micromanipulating small objects for precision manufacturing and biotechnology with high accuracy in a relatively large workspace
Keywords
electromagnetic actuators; force control; micromanipulators; displacement; electrical actuator; electromagnetic microgripper; force control; micromanipulators; moving coil actuator; resonant frequency; Assembly systems; Coils; Costs; Displacement measurement; Electric variables measurement; Electromagnetic forces; Electromagnetic measurements; Fingers; Grippers; Hydraulic actuators;
fLanguage
English
Publisher
ieee
Conference_Titel
Robotics and Automation, 1999. Proceedings. 1999 IEEE International Conference on
Conference_Location
Detroit, MI
ISSN
1050-4729
Print_ISBN
0-7803-5180-0
Type
conf
DOI
10.1109/ROBOT.1999.774037
Filename
774037
Link To Document