Title :
Investigation on the start-up of low wattage metal halide lamp controlled by low-frequency square-wave ballast
Author :
Guo, Rong ; Yang, Yongbing ; Qian, Zhaoming
Author_Institution :
Coll. of Electr. Eng., Zhejiang Univ., Hangzhou
Abstract :
Using conventional three-stage low-frequency square-wave electronic ballast, low-wattage MH lamps may have trouble in starting-up instantly and smoothly. This paper investigates the special starting-up characteristics of low-wattage MH lamps and presents some novel control strategy according to the lamps´ special characteristics. A prototype of 70 W electronic ballast with the new control circuit designs was constructed and experimental results verified the novel control strategy can greatly increase the probability for lamps to successfully start up instantly and smoothly
Keywords :
frequency control; lamp accessories; metal vapour lamps; 70 W; control circuit design; electronic ballast; metal halide lamp; square-wave ballast; Buck converters; Circuits; Educational institutions; Electrodes; Electronic ballasts; Ignition; Lamps; Power control; Steady-state; Voltage;
Conference_Titel :
Industrial Electronics Society, 2005. IECON 2005. 31st Annual Conference of IEEE
Conference_Location :
Raleigh, NC
Print_ISBN :
0-7803-9252-3
DOI :
10.1109/IECON.2005.1569009