  • Abstract
    Three-phase PWM (active) rectifiers are connected to the line power through inductance or LCL filter. LCL filter is more effective (better attenuates switching harmonics), however such solution causes stability problems. In order to assure stable operation either a damping resistor or active damping algorithm has to be used. However, extra resistor causes additional losses and active damping algorithm usually needs extra sensors. Therefore, this paper shows simulation and experimental results of a simple AC voltage sensorless active damping solution suitable for industrial application
  • Keywords
    PWM rectifiers; damping; losses; passive filters; power filters; AC voltage sensorless active damping solution; LCL filter; damping resistor; inductance; losses; stability; three-phase PWM rectifier; Capacitors; Damping; IEC standards; Inductance; Power harmonic filters; Pulse width modulation; Pulse width modulation converters; Rectifiers; Resistors; Resonance;