DocumentCode :
2914905
Title :
Development of a high speed X-ray tomography system for multiphase flow imaging
Author :
Morton, E.J. ; Luggar, R.D. ; Key, M.J. ; Kundu, A. ; Távora, L. M N ; Gilboy, W.B.
Author_Institution :
Dept. of Phys., Surrey Univ., Guildford, UK
Volume :
2
fYear :
1998
fDate :
1998
Firstpage :
995
Abstract :
This paper describes a new system for quantitative measurement of multiphase flow. It is based on the use of high speed (50 frames per second) X-ray tomographic imaging. This requires a new X-ray tube concept to be implemented, together with an annular detector array and data acquisition system. A pressurised krypton microgap detector is being developed to give 90% quantum efficiency for detection of Kα radiation from the silver anode X-ray tube. Results from simulation work are presented to justify the overall design strategy selected
Keywords :
X-ray detection; X-ray imaging; X-ray tubes; data acquisition; flow visualisation; high-speed techniques; multiphase flow; tomography; Ag; Kα radiation; Kr; X-ray tube; annular detector array; data acquisition; high speed X-ray tomography; multiphase flow imaging; pressurised Kr microgap detector; quantitative measurement; simulation work; Data acquisition; Fluid flow measurement; Optical imaging; Radiation detectors; Sensor arrays; Silver; X-ray detection; X-ray detectors; X-ray imaging; X-ray tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1998. Conference Record. 1998 IEEE
Conference_Location :
Toronto, Ont.
ISSN :
1082-3654
Print_ISBN :
0-7803-5021-9
Type :
conf
DOI :
10.1109/NSSMIC.1998.774334
Filename :
774334
Link To Document :
بازگشت