DocumentCode
2915551
Title
Fault finding in a 1 MW photovoltaic plant by reflectometry
Author
Schirone, L. ; Califano, F.P. ; Moschella, U. ; Rocca, U.
Author_Institution
Terza Univ. di Roma, Italy
Volume
1
fYear
1994
fDate
5-9 Dec 1994
Firstpage
846
Abstract
Time domain reflectometry has been used for diagnostic monitoring of a large size photovoltaic (PV) giant in operating conditions. By analysing the waveforms obtained when a step-voltage excitation is propagated down the electrical line connecting the PV generators to the inverter, we were able to detect, identify and localise the most common fault conditions, such as breaks of the circuit, insulation defects, wiring anomalies. Best compromise between analysis time and precision was achieved by testing groups of three paralleled strings (panels): in this way we were able to detect in a short time whether a fault was present, while its position was separately determined with a good precision by repeating the test on the single strings. The whole 1 MW PV plant was tested in a couple of days. Finally, we discuss some economical aspects of this fault finding technique
Keywords
fault diagnosis; fault location; monitoring; solar cell arrays; solar cells; solar power stations; time-domain reflectometry; voltage measurement; 1 MW; PV generators; diagnostic monitoring; economical aspects; electrical line; fault finding; inverter; operating conditions; photovoltaic plant; step-voltage excitation; time domain reflectometry; Circuit faults; Condition monitoring; Electrical fault detection; Fault diagnosis; Inverters; Joining processes; Photovoltaic systems; Reflectometry; Solar power generation; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Energy Conversion, 1994., Conference Record of the Twenty Fourth. IEEE Photovoltaic Specialists Conference - 1994, 1994 IEEE First World Conference on
Conference_Location
Waikoloa, HI
Print_ISBN
0-7803-1460-3
Type
conf
DOI
10.1109/WCPEC.1994.520093
Filename
520093
Link To Document