Abstract
A mathematical model of the PAC-UF membrane flux through a number of factors and quantitative characterization, based on Darcy´s law, has been derived. Meanwhile, PAC-UF combined process was applied to treat Gan River micro-polluted raw water. Validity of the mathematical model is verified with the experiment. Furthermore, for different operation pressure and running time, the result shows that the model can exactly predict the membrane flux, water production, time to achieve amount of needed water and a chemical cleaning of the membrane. These parameters can be used in guiding the engineering design and operation to treat Gan River micro-polluted raw water with PAC-UF combined process.
Keywords
activated carbon; flow through porous media; membranes; rivers; ultrafiltration; wastewater treatment; water pollution; Darcy´s law; Gan river micropolluted raw water; PAC-UF membrane flux; engineering design; mathematical model; membrane chemical cleaning; water production; Biomembranes; Chemicals; Cleaning; Mathematical model; Resistance; Water pollution; Water resources; PAC-UF; mathematical model; membrane flux; water production;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Distributed Control and Intelligent Environmental Monitoring (CDCIEM), 2011 International Conference on
Conference_Location
Changsha
Print_ISBN
978-1-61284-278-3
Electronic_ISBN
978-0-7695-4350-5
Type
conf
DOI
10.1109/CDCIEM.2011.503
Filename
5747855
Link To Document