• DocumentCode
    2918000
  • Title

    A Heat Energy Assessment Method of the Plant Secondary Effluent as Cold and Heat Sources for Heat Pump

  • Author

    Zhao-yi, Zhuang ; Cheng-hu, Zang ; Qiong, Sun ; De-xing, Sun

  • Author_Institution
    Sch. of Municipal & Environ. Eng., Harbin Inst. of Technol., Harbin, China
  • fYear
    2011
  • fDate
    19-20 Feb. 2011
  • Firstpage
    655
  • Lastpage
    659
  • Abstract
    The sewage plant secondary effluent is full of low cold and heat energy, drawing cold and heat energy by direct sewage source heat pump and using it can provide heating in winter and cooling in summer. This paper introduced technical solutions of the direct sewage source heat pump system, besides, it gave the evaluating method of sewage effluent cold and heat energy - the hourly analysis method, taking a sewage plant in Qingdao as an example and comparing it with the common engineering assessment method, the results show that this method has more engineering practicability.
  • Keywords
    cooling; effluents; heat pumps; heating; cold sources; cooling; direct sewage source heat pump system; heat energy assessment; heat sources; heating; sewage effluent cold; sewage plant secondary effluent; Computers; Decision support systems; Distributed control; Monitoring; cold; heat energy assessment; heat pump; heat source; secondary effluent;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Distributed Control and Intelligent Environmental Monitoring (CDCIEM), 2011 International Conference on
  • Conference_Location
    Changsha
  • Print_ISBN
    978-1-61284-278-3
  • Electronic_ISBN
    978-0-7695-4350-5
  • Type

    conf

  • DOI
    10.1109/CDCIEM.2011.55
  • Filename
    5747901