DocumentCode
2919582
Title
Grey Decision on Oil Distillation Tower Top Exchangers Maintenance Overhaul
Author
Wang, Zhengfang ; Wang, Yong ; Wang, Weiqiang ; Cheng, Yiyuan ; Qi, Hui ; Qu, Dawei
Author_Institution
Inst. of Mech. Eng., China Univ. of Pet. CUP, Dongying
fYear
2009
fDate
20-22 Feb. 2009
Firstpage
187
Lastpage
190
Abstract
The exchangers on the top of tower exposed to wash erosion seriously when Shengli refinery processed Middle-east crude oil. Used grey system theory, aimed at general tube-shell exchangers and helix-baffled structure, tube of 20 carbon steel with TH847 coating, 20 steel aluminizing, 316L and dual phase steel, carried on grey decision. For exchangers rebuilding project, grey target decision shows that helix-baffled exchangers with 20+TH847 coating tube is the best preference plan, while grey incidence decision shows that the helix-baffled structure with 20 carbon steel aluminizing tube is the preferential plan. In general, helix-baffled structure is better than general contractures, should adopt advanced manufacture technology to lower the fabricate difficulty.
Keywords
carbon steel; crude oil; decision theory; distillation; grey systems; heat exchangers; maintenance engineering; oil refining; petroleum industry; pipes; shells (structures); FeCJk; Shengli refinery; TH847 coating; carbon steel aluminizing tubes; crude oil; grey decision; grey system theory; helix-baffled structures; maintenance; oil distillation tower top exchangers; tube-shell exchangers; Coatings; Corrosion; Heat transfer; Manufacturing; Mechanical engineering; Petroleum; Poles and towers; Refining; Safety; Steel; grey decision; grey incidence decision; grey target decision; maintenance overhaul;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Computer Technology, 2009 International Conference on
Conference_Location
Macau
Print_ISBN
978-0-7695-3559-3
Type
conf
DOI
10.1109/ICECT.2009.108
Filename
4795947
Link To Document