DocumentCode
2921439
Title
A new continuous input current charge pump power factor correction (CIC-CPPFC) electronic ballast
Author
Qian, Jinrong ; Lee, Fred C. ; Yamauchi, Tokushi
Author_Institution
Bradley Dept. of Electr. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA, USA
Volume
3
fYear
1997
fDate
5-9 Oct 1997
Firstpage
2299
Abstract
A continuous input current charge pump power factor correction (CIC-CPPFC) electronic ballast is proposed in this paper. Circuit derivation and unity power factor condition using the charge pump concept are derived and analyzed. The power switch only deals with the resonant load current which is the same as the two-stage approach. The developed electronic ballast has continuous input line current so that a small line input filter can be used. The proposed CIC-CPPFC electronic ballast was implemented and tested. It is shown that switching current stress is only half of the integrated single stage electronic ballast. 0.992 power factor and 10.5% THD can be achieved with two 45-watt fluorescent lamps
Keywords
fluorescent lamps; harmonic distortion; invertors; lamp accessories; power convertors; power factor correction; power system harmonics; switches; 45 W; AC/DC converter; DC/AC inverter; DC/DC converter; circuit derivation; continuous input current charge pump PFC ballast; continuous input line current; electronic ballast; fluorescent lamps; power switch; resonant load current; small line input filter; switching current stress; total harmonic distortion; two-stage approach; unity power factor; Charge pumps; Circuits; Electronic ballasts; Electronic equipment testing; Filters; Fluorescent lamps; Power factor correction; Reactive power; Resonance; Stress;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 1997. Thirty-Second IAS Annual Meeting, IAS '97., Conference Record of the 1997 IEEE
Conference_Location
New Orleans, LA
ISSN
0197-2618
Print_ISBN
0-7803-4067-1
Type
conf
DOI
10.1109/IAS.1997.626384