DocumentCode
2924732
Title
P3-2: Some possibilities for reducing after-cavity interaction in gyrotrons
Author
Sinitsyn, Oleksandr V. ; Nusinovich, Gregory S. ; Antonsen, Thomas M., Jr.
Author_Institution
Inst. for Res. in Electron. & Appl. Phys., Univ. of Maryland, College Park, MD, USA
fYear
2010
fDate
18-20 May 2010
Firstpage
333
Lastpage
334
Abstract
After-cavity interaction (ACI) in high-power gyrotrons results in significant efficiency degradation and limits the opportunities for utilizing depressed collectors. In this paper we analyze possibilities for minimizing this effect.
Keywords
gyrotrons; after-cavity interaction; depressed collectors; efficiency degradation; high-power gyrotrons; Cyclotrons; Electromagnetic waveguides; Electron beams; Frequency; Gyrotrons; Magnetic analysis; Magnetic fields; Magnetic resonance; Optical coupling; Physics; after-cavity interaction; depressed collectors; gyrotrons; interaction efficiency;
fLanguage
English
Publisher
ieee
Conference_Titel
Vacuum Electronics Conference (IVEC), 2010 IEEE International
Conference_Location
Monterey, CA
Print_ISBN
978-1-4244-7098-3
Type
conf
DOI
10.1109/IVELEC.2010.5503415
Filename
5503415
Link To Document