Abstract :
Long-term field experience and the knowledge of the condition of stator bar insulation after long periods of operation are key points for ensuring reliable operation of stator windings. The ALSTOM Micadur® insulation system, first introduced for generators in 1958, has such long-term field experience. This system is in service over the whole power range of hydro and turbo generators, represented by a fleet of more than 10,000 machines between 5 MVA and 1944 MVA. ALSTOM had the opportunity to investigate the condition of 8 operation-aged Micadur® bars of a hydro generator, since the owner was replacing the stator core and stator winding.
Keywords :
hydroelectric generators; machine insulation; stators; turbogenerators; ALSTOM Micadur; Micadur bars; apparent power 5 MVA to 1944 MVA; hydro generator stator bars; insulation condition; long-term field experience; stator bar insulation; stator windings; turbogenerators; Bars; Generators; Insulation; Stator bars; Stator windings; Windings; Generators; Insulation System; Lifetime; Lifetime Assessment; Mica-Insulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation Conference (EIC), 2011
Conference_Location :
Annapolis, MD
ISSN :
pending
Print_ISBN :
978-1-4577-0278-5
Electronic_ISBN :
pending
Type :
conf
DOI :
10.1109/EIC.2011.5996155
Filename :
5996155
Link To Document :
بازگشت