DocumentCode :
2927754
Title :
Critical cavity size producing internal discharges in stator bar ground wall insulation
Author :
Turgeon, A. ; Hudon, C. ; Nguyen, Duc N.
Author_Institution :
IREQ, Inst. de Rech. d´Hydro-Quebec, Varennes, QC, Canada
fYear :
2011
fDate :
5-8 June 2011
Firstpage :
318
Lastpage :
322
Abstract :
Partial discharges (PDs) cause degradation of the generator stator bars insultation. The use of mica in this insulation system prevents small internal PDs from reducing the expected life of the equipment. However, some cavities may be the cause of a more significant PD presence and accelerate the aging of the insulation system. A method that uses the Paschen law and numerical simulations is presented for determining critical cavity sizes that produce significant PDs.
Keywords :
ageing; insulation; numerical analysis; partial discharges; stators; Paschen law; aging; critical cavity size; generator stator bars insultation; ground wall insulation; insulation system; internal discharges; numerical simulations; partial discharges; Cavity resonators; Copper; Discharges; Electric fields; Insulation; Partial discharges; Paschen law; electric field; gas breakdown; insulation;