• DocumentCode
    2927778
  • Title

    Tracking stator bar condition by on-line partial discharge measurements

  • Author

    McDermid, W. ; Black, T.

  • Author_Institution
    Manitoba Hydro, Winnipeg, MB, Canada
  • fYear
    2011
  • fDate
    5-8 June 2011
  • Firstpage
    323
  • Lastpage
    326
  • Abstract
    A total of 24 new stator bar windings in hydrogenerators were equipped with 80 pF permanent couplers for on-line partial discharge measurements beginning in 1979. This paper summarizes some of the changes in the PD characteristics that have occurred over the years and correlates significant changes with the condition of the windings.
  • Keywords
    hydroelectric generators; partial discharge measurement; stators; PD characteristics; capacitance 80 pF; hydrogenerators; online partial discharge measurements; permanent couplers; stator bar windings; tracking stator bar condition; Couplers; Partial discharge measurement; Stator bars; Stator windings; Stress control; Windings; partial discharge; rotating machines;