• DocumentCode
    2928876
  • Title

    2.3: Reliability test of the ITER 170GHz gyrotron and development of the two-frequency gyrotron

  • Author

    Kajiwara, Ken ; Oda, Yasuhisa ; Kasugai, Atsushi ; Takahashi, Koji ; Sakamoto, Keishi

  • Author_Institution
    Japan Atomic Energy Agency, Naka, Japan
  • fYear
    2010
  • fDate
    18-20 May 2010
  • Firstpage
    31
  • Lastpage
    32
  • Abstract
    Reliability of the 170 GHz ITER gyrotron is tested in JAEA. The 800 kW/600 sec pulse with 52-57% efficiency is repeated with interval of 20 min in 8 days. The 72 shots of 600 sec were successfully achieved out of 88 shots. The success rate was 82 %. It shows the realistic reliability for the gyrotron operation for ITER. The next step is a development of a multi frequency gyrotron. Preliminary test of the two-frequency gyrotron is performed. The 170 GHz and 136 GHz oscillations are successfully attained at short pulse (0.5 ms) and long pulse (10 sec). In the short pulse experiments, the maximum power of 1.3 MW is obtained at both frequencies.
  • Keywords
    fusion reactor ignition; gyrotrons; plasma radiofrequency heating; plasma toroidal confinement; plasma transport processes; ITER gyrotron operation; ITER gyrotron reliability test; JAEA; frequency 136 GHz; frequency 170 GHz; power 1.3 MW; power 800 kW; time 0.5 ms; time 10 s; time 600 s; two frequency gyrotron; Gyrotrons; Testing; 2 frequencies; Gyrotron; ITER; reliability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Vacuum Electronics Conference (IVEC), 2010 IEEE International
  • Conference_Location
    Monterey, CA
  • Print_ISBN
    978-1-4244-7098-3
  • Type

    conf

  • DOI
    10.1109/IVELEC.2010.5503617
  • Filename
    5503617