Title :
Calibration and fluctuation of the secular frequency peak amplitude versus initial condition distribution of the ion cloud confined into a three-dimensional quadrupole ion trap using a Fourier transform operating mode and a steady ion flow injection mode
Author :
Janulyte, A. ; Andre, J. ; Carette, M. ; Mercury, M. ; Reynard, C. ; Zerega, Y.
Author_Institution :
Lab. Chimie Provence, Univ. Aix-Marseille I, II et III, Marseille, France
fYear :
2009
fDate :
7-10 June 2009
Firstpage :
1
Lastpage :
7
Abstract :
A specific Fourier transform operating mode is applied to a 3D quadrupolar ion trap for mass analysis (Fourier Transform Quadrupolar Ion Trap (FTQIT) Operating Mode or Mass Spectrometer). With this operating mode, an image signal, which is representative of the collective motion of simultaneously confined ions, is made up from a set of recorded time-of-flight histograms. In an ion trap, the secular frequency of ion motion depends on m/z ratio of the ion. By Fourier transformation of the image signal, one observes the frequency peak of each confined ionic species. When only one ionic species is confined, the peak amplitude is proportional to the maximal amplitude of the image signal.The maximal amplitude of the image signal is expressed according to the operating parameters, the initial conditions of the ions and the number of ions. Simulation tools lead to fluctuation calculation of the maximal amplitude of the image signal. Two origins are explored: (1) the fluctuation of the numbers of ions according to the steady ion flow injection mode (SIFIM) used with this operating mode and (2) the distribution fluctuation of the initial positions and velocities. Initial confinement conditions, obtained with SIFIM injection mode, lead to optimal detection with small fluctuations of the peak amplitude for Fourier transform operating mode applied to an ion trap.
Keywords :
Fourier transforms; ion sources; mass spectrometers; particle traps; 3D quadrupolar ion trap; Fourier transform operating mode; collective motion; external ion source; fluctuation calculation; fluctuation distribution; image signal; initial condition distribution; initial confinement condition; mass analysis; mass spectrometer; operating mode; operating parameter; optimal detection; secular frequency peak amplitude; simulation tool; steady ion flow injection mode; three-dimensional quadrupole ion trap; time-of-flight histogram; Calibration; Clouds; Dissolved gas analysis; Fluctuations; Fourier transforms; Frequency; Histograms; Mass spectroscopy; Performance analysis; Prototypes; Fourier Transformation; Ion trap; Mass spectrometry; On-line analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA), 2009 First International Conference on
Conference_Location :
Marseille
Print_ISBN :
978-1-4244-5207-1
Electronic_ISBN :
978-1-4244-5208-8
Type :
conf
DOI :
10.1109/ANIMMA.2009.5503716
Filename :
5503716
Link To Document :
بازگشت