Title : 
Common-view technique applied to the link CENAM-LAPEM
         
        
            Author : 
Molina-Lopez, V. ; Lopez-Regalado, G. ; Montonya-Vargas, A.A. ; Lopez-Romero, J.M. ; Jardon-Aguilar, H. ; Figoeron-Estrada, J.M.
         
        
            Author_Institution : 
Time & Frequency Div., Centro Nacional de Metrol., Mexico
         
        
        
        
        
        
            Abstract : 
In order to improve the quality of its time and frequency services the Mexican electricity company (Comision Federal de Electricidad, CFE) by its test on equipment and materials laboratory (Laboratorio de Pruebas y Equipos de Mexico, LAPEM), requires traceability to time and frequency Mexican primary standards. A TTR-6A GPS receiver is being employed by LAPEM in order to get this objective, and the common-view technique between CENAM-LAPEM is considered.
         
        
            Keywords : 
Global Positioning System; atomic clocks; calibration; frequency standards; synchronisation; CENAM-LAPEM link; Mexican primary standards; TTR-6A GPS receiver; calibration; clock comparisons; common-view technique; time and frequency services; time transfer; traceability; Calibration; Clocks; Frequency control; Global Positioning System; NIST; Oscillators; Receiving antennas; Satellites; Stability; USA Councils;
         
        
        
        
            Conference_Titel : 
Precision Electromagnetic Measurements Digest, 1998 Conference on
         
        
            Conference_Location : 
Washington, DC, USA
         
        
            Print_ISBN : 
0-7803-5018-9
         
        
        
            DOI : 
10.1109/CPEM.1998.699785