DocumentCode :
2932313
Title :
Study of Solar Radiation Factor for the Parabolic Trough Solar Thermal Power Plant in Typical Chinese Sites
Author :
Qu, Hang ; Yu, Xiao ; Fan, Qinglai ; Zhao, Jun
Author_Institution :
Sch. of Food Eng., Ludong Univ., Yantai, China
fYear :
2011
fDate :
25-28 March 2011
Firstpage :
1
Lastpage :
4
Abstract :
This paper studied the effect radiation of the parabolic trough concentrator thoroughly, and it was revealed that Incident Direct Insolation (IDR) should be used to evaluate the solar resource for locating a PTSTP plant, instead of Direct Normal Insolation (DNI), for it takes latitude into consideration. Lhasa, with latitude of 29.43, and Naiman, with latitude of 43.47, were studied respectively, and the results indicates that Lhasa´s annual DNI level is 14.33% higher than IDR, while it is 22.43 higher in Naiman. Also performance of a 35MW-parabolic trough solar power plant was simulated for 9 typical locations in China, and the results verified the advantage of IDR to DNI as a plant siting factor.
Keywords :
solar power stations; solar radiation; thermal power stations; direct normal insolation; incident direct insolation; parabolic trough concentrator; parabolic trough solar thermal power plant; plant siting factor; power 35 MW; solar radiation factor; typical Chinese sites; Apertures; Arrays; Azimuth; Educational institutions; Optical losses; Power generation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
Conference_Location :
Wuhan
ISSN :
2157-4839
Print_ISBN :
978-1-4244-6253-7
Type :
conf
DOI :
10.1109/APPEEC.2011.5748668
Filename :
5748668
Link To Document :
بازگشت