Title : 
AC-DC difference precision measurement of μpot
         
        
            Author : 
Wei, Yih-cheng ; Tsai, Hsiu-Ju
         
        
            Author_Institution : 
Electr. Meas. Lab., Ind. Technol. Res. Inst., Hsinchu, Taiwan
         
        
        
        
        
        
            Abstract : 
Many electrical standard laboratories use μpots as the primary standards for low ac voltage measurement. To determine the ac-dc difference of a μpot usually requires a transfer standard which has high input impedance for the standard values transferred from a standard μpot through a step-down procedure. In order to lower the uncertainty of the μpot ac-dc difference measurement, after several step-down procedures at low voltage range, a precision comparison method is introduced
         
        
            Keywords : 
measurement standards; transfer standards; voltage measurement; μpots; AC-DC difference; comparison method; electrical standard laboratories; precision measurement; primary standards; step-down procedures; transfer standard; voltage measurement; Frequency; Impedance measurement; Laboratories; Low voltage; Measurement standards; Resistors; Testing; Uncertainty; Voltage control; Voltage measurement;
         
        
        
        
            Conference_Titel : 
Instrumentation and Measurement Technology Conference, 1999. IMTC/99. Proceedings of the 16th IEEE
         
        
            Conference_Location : 
Venice
         
        
        
            Print_ISBN : 
0-7803-5276-9
         
        
        
            DOI : 
10.1109/IMTC.1999.776137