DocumentCode
2938406
Title
Research of the Electromagnetic compatibility problems caused as putting heavy and weak current facilities together in the subway system
Author
Jian Jiao ; Dan Shi ; Yu-Ming Zhang
Author_Institution
Sch. of Electron. Eng., Beijing Univ. of Posts & Telecommun., Beijing, China
fYear
2012
fDate
6-9 Nov. 2012
Firstpage
387
Lastpage
392
Abstract
Based on CST, models of the heavy current facilities in the subway system have been built and the simulation has been completed to acquire the radiation of EMI. By comparing the results of the simulation with the corresponding results of the actual measurement, the models are modified until the simulation of the models could mainly reflect the situation of Electromagnetic field around the heavy current facilities correctly. With the procedure of actual measurement, modeling, simulation, analysis and modification, the shortest distance between the heavy and weak current facilities in the subway station in the normal working condition could be proposed. A more reasonable layout of all facilities could also be acquired so that the resource of the rooms could be saved and the administration of the whole station could be easier.
Keywords
electromagnetic compatibility; electromagnetic interference; EMI radiation; electromagnetic compatibility problems; electromagnetic field; heavy current facilities; subway system; weak current facilities; Current measurement; Electromagnetic interference; Layout; Rectifiers; Switches; Transient analysis; CST; EMC; heavy and weak current facilities; shortest distance;
fLanguage
English
Publisher
ieee
Conference_Titel
Environmental Electromagnetics (CEEM), 2012 6th Asia-Pacific Conference on
Conference_Location
Shanghai
Print_ISBN
978-1-4673-0030-8
Type
conf
DOI
10.1109/CEEM.2012.6410650
Filename
6410650
Link To Document