• DocumentCode
    2938984
  • Title

    Fast and accurate calibration of an X-ray imager to an electromagnetic tracking system for interventional cardiac procedures

  • Author

    Lang, Andrew ; Stanton, Douglas ; Parthasarathy, Vijay ; Jain, Ameet

  • Author_Institution
    Philips Res. North America, Briarcliff Manor, NY, USA
  • fYear
    2010
  • fDate
    Aug. 31 2010-Sept. 4 2010
  • Firstpage
    1868
  • Lastpage
    1873
  • Abstract
    Cardiovascular disease affects millions of Americans each year. Interventional guidance systems are being developed as treatment options for some of the more delicate procedures, including targeted stem cell therapy. As advanced systems for such types of interventional guidance are being developed, electromagnetic (EM) tracking is coming in demand to perform navigation. To use this EM tracking technology, a calibration is necessary to register the tracker to the imaging system. In this paper we investigate the calibration of an Xray imaging system to EM tracking. Two specially designed calibration phantoms have been designed for this purpose, each having a rigidly attached EM sensor. From a clinical usability point-of-view, we propose to divide this calibration problem into two steps: i) an initial calibration of the EM sensor to the phantom design using an EM tracked needle to trace out grooves in the phantom surface and ii) segmentation from Xray images and 3D reconstruction of beads embedded in the phantom in a known geometric pattern. Combining these two steps yields an X-ray-to-EM calibration accuracy of less than 1 mm when overlaying an EM tracked needle on X-ray images.
  • Keywords
    calibration; cardiovascular system; diagnostic radiography; diseases; image reconstruction; image segmentation; medical image processing; patient treatment; phantoms; tracking; 3D reconstruction; EM sensor; X-ray imager; X-ray-to-EM calibration accuracy; calibration phantoms; cardiovascular disease; electromagnetic tracking system; image segmentation; interventional cardiac procedures; interventional guidance systems; navigation; targeted stem cell therapy; Lead; Navigation; Phantoms; Calibration; Cardiac Surgical Procedures; Computer Graphics; Equipment Design; Humans; Image Processing, Computer-Assisted; Phantoms, Imaging; Radiation; Radiography; Reproducibility of Results; X-Rays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2010 Annual International Conference of the IEEE
  • Conference_Location
    Buenos Aires
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4123-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2010.5627160
  • Filename
    5627160