DocumentCode :
293902
Title :
Performance of the endcap Cherenkov ring imaging detector at SLD
Author :
Abe, K. ; Antilogus, P. ; Aston, D. ; Baird, K. ; Bean, A. ; Ben-David, R. ; Bienz, T. ; Bird, F. ; Caldwell, D.O. ; Cavalli-Sforza, M. ; Coller, J. ; Coyle, P. ; Coyne, D. ; Dasu, S. ; Dima, M. ; Dolinsky, S. ; d´Oliveira, A. ; Duboscq, J. ; Dunwoodie, W
Author_Institution :
Dept. of Phys., Tohoku Univ., Sendai, Japan
Volume :
1
fYear :
1994
fDate :
Oct. 30 1994-Nov. 5 1994
Firstpage :
235
Abstract :
We present the Cherenkov Ring Imaging Detector in the endcap regions of the SLD detector and report on initial performance during the 1993 and 1994 runs at the SLC. The endcap CRID was completed and commissioned in 1993 and is fully operational for the 1994 run. First Cherenkov rings have been observed. The endcap CRID detectors and fluid systems are described and initial operational experience is discussed.<>
Keywords :
Cherenkov counters; SLD; endcap CRID detectors; endcap Cherenkov ring imaging detector; fluid systems; initial operational experience; Birds; Computed tomography; Focusing; Laboratories; Linear accelerators; Particle measurements; Physics; Radiation detectors; Superluminescent diodes; Velocity measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
Conference_Location :
Norfolk, VA, USA
Print_ISBN :
0-7803-2544-3
Type :
conf
DOI :
10.1109/NSSMIC.1994.474420
Filename :
474420
Link To Document :
بازگشت