Title :
Synthetic Aperture Ultrasonic Imaging in Pipeline Inspection
Author :
Du, Yinghua ; Jin, Shijiu
Author_Institution :
State Key Lab. of Precision Meas. Technol. & Instrum., Tianjin Univ., Tianjin, China
Abstract :
An ultrasonic scanning system is built for pipeline inspection, using SAFT (Synthetic Aperture Focusing Technology) imaging method. The SAFT imaging technology is investigated. The simulation is done by MATLAB to decide the key parameters. Most system design is accomplished by FPGA, and the parallel processing method is employed to accelerate the image reconstruction time.
Keywords :
image reconstruction; inspection; parallel processing; pipelines; ultrasonic imaging; FPGA; MATLAB; SAFT imaging; image reconstruction; parallel processing; pipeline inspection; synthetic aperture focusing technology; synthetic aperture ultrasonic imaging; ultrasonic scanning system; Delay; Focusing; Image reconstruction; Inspection; Phase measurement; Phased arrays; Pipelines; Reconstruction algorithms; Ultrasonic imaging; Ultrasonic variables measurement; FPGA; SAFT; image reconstruction;
Conference_Titel :
Measuring Technology and Mechatronics Automation, 2009. ICMTMA '09. International Conference on
Conference_Location :
Zhangjiajie, Hunan
Print_ISBN :
978-0-7695-3583-8
DOI :
10.1109/ICMTMA.2009.649