            Abstract : 
The Hewlett Packard HDMP-1000 G-Link transmitter and receiver chip set was tested for an event builder application. The relock time of the serial link when a data path is changed is less than 30 μs provided fill frames are transmitted. With a 1 kHz data path switching rate, this results in less than a 3% data rate inefficiency due to re-synchronization which makes the HP G-Link chip set effective for use in a large event builder for a hadron collider experiment
         
        
            Keywords : 
data acquisition; high energy physics instrumentation computing; 1 kHz; 30 ns; HDMP-1000 G-Link chip set; Hewlett Packard; data path switching rate; data rate inefficiency; event builder; re-synchronization; receiver; relock time; serial link; transmitter; Clocks; Detectors; Frequency synchronization; Hardware; Laboratories; Life estimation; Switches; Testing; Traffic control; Transmitters;
         
        
        
        