• DocumentCode
    294042
  • Title

    FB-TCT truncation suppression by combining two shifted scans with extrapolation techniques

  • Author

    Kadrmas, Dan J. ; Jaszczak, Ronald J. ; Coleman, R.E.

  • Author_Institution
    Duke Univ. Med. Center, Durham, NC, USA
  • Volume
    3
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1247
  • Abstract
    The convergent beam geometry of fan beam (FB) transmission computed tomography (TCT) often results in image truncation; producing ring artifacts, distorted body contours, and erroneously high pixel values in filtered-backprojection reconstructed images. A method is described which reduces the degree of truncation by performing two patient-shifted FB-TCT scans, and then uses an extrapolation technique to complete the projection set. By scanning the patient when shifted left and right of the axis of rotation, the effective field-of-view is substantially increased. If any truncation remains, the total amount of attenuating medium present is calculated from untruncated views. For truncated views, missing projections are filled until this total is reached. The method has been tested by scanning a large (38×26 cm) anthropomorphic thorax phantom on a three camera single photon emission computed tomography (SPECT) system. The two run method was successful in reducing the degree of truncation to only a slight amount for this phantom. Application of the extrapolation method helped suppress ring artifacts in this case. To further test the extrapolation method projection sets were truncated to a greater degree using software. Extrapolation helped improve SPECT attenuation compensation, but some artifact remained in the images
  • Keywords
    extrapolation; image reconstruction; medical image processing; single photon emission computed tomography; FB-TCT truncation suppression; SPECT; anthropomorphic thorax phantom; convergent beam geometry; extrapolation techniques; fan beam transmission computed tomography; medical diagnostic imaging; missing projections; nuclear medicine; ring artifacts; rotation axis; shifted scans; two run method; Anthropomorphism; Computational geometry; Computed tomography; Extrapolation; Image converters; Image reconstruction; Imaging phantoms; Pixel; System testing; Thorax;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474600
  • Filename
    474600