• DocumentCode
    2940691
  • Title

    Analysis on the Back-Pressure Optimum Operation of the Direct Air-Cooled Condenser

  • Author

    Zhao, Hongbin ; Wu, Haixia ; Cao, Ling

  • Author_Institution
    Sch. of Mechatron. Eng., China Univ. of Pet. Beijing, Beijing, China
  • fYear
    2011
  • fDate
    25-28 March 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The back-pressure of the direct air-cooled unit directly affects the system running economy. Based on the thermodynamic model of the air-cooled system, according to the basic method of seeking the optimal back-pressure in theory, this article has established the back-pressure optimization mathematical model of the air-cooled unit to obtain the optimal back-pressure under the actual operating conditions, instructed on-site staffs to adjust fan speed, and made the unit reach the most economic operating conditions, so as to achieve energy-saving purpose in the direct air-cooled thermal power plant.
  • Keywords
    condensers (steam plant); thermal power stations; back-pressure; direct air-cooled condenser; direct air-cooled unit; economic operating conditions; mathematical model; optimum operation; system running economy; thermal power plant; thermodynamic model; Coal; Heat transfer; Mathematical model; Optimization; Software; Turbines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
  • Conference_Location
    Wuhan
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4244-6253-7
  • Type

    conf

  • DOI
    10.1109/APPEEC.2011.5749081