DocumentCode :
2942447
Title :
Research on Indicators of Early Warning in Low Frequency Oscillation Based on Energy Function Theory
Author :
Huang, Yong ; Dong, Chao ; Liu, Dichen ; Liao, Qingfen ; Chen, Enze ; Zeng, Zheng
Author_Institution :
Sch. of Electr. Eng., Wuhan Univ., Wuhan, China
fYear :
2011
fDate :
25-28 March 2011
Firstpage :
1
Lastpage :
5
Abstract :
This paper simplified the classical transient energy function based on center of inertia, improved the classical indicators of the stability margin, and put forward the indicator of the stability margin increment The indicator was established on the basis of the tie-line observational section in power system, and the calculation was simple and convenient, not only achieving early warnings of low frequency oscillation under multiple disturbances, but also can be used to judge the seriousness of disturbances. The indicator has the potential of online applications. The simulation on NEW ENGLAND 10 machines and the actual system testified the validation of the method.
Keywords :
indicators; power system measurement; power system stability; center of inertia; early warning; energy function theory; indicators; low frequency oscillation; multiple disturbances; stability margin; tie-line observational section; Oscillators; Power system dynamics; Power system stability; Stability criteria; Transient analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
Conference_Location :
Wuhan
ISSN :
2157-4839
Print_ISBN :
978-1-4244-6253-7
Type :
conf
DOI :
10.1109/APPEEC.2011.5749175
Filename :
5749175
Link To Document :
بازگشت