Abstract :
In microwave breast imaging, image reconstruction involves tomographic reconstruction, radar-based imaging, or some combination of both methods (J. F. Deprez, et al., PIER B, 42, 381-403, 2012). With radar-based techniques, similar basic processing steps, i.e., calibration and skin subtraction are taken to process the raw data prior to their deployment in Kirchhoff summation (image focusing). Usually, minimal consideration is given to improve the temporal resolution of the raw signals. However, the spatial resolution associated with the reconstructed image is a function of the temporal resolution of raw data. With simple breast phantoms, i.e., homogeneous breast volume with a single inclusion, an image with low spatial resolution may give a relatively accurate estimate of inclusion location, however lacks sensitivities to the changes in its size. With complicated breast phantoms, i.e., heterogeneous breast volume with multiple malignant and benign inclusions, low imaging resolution may blur malignant inclusions into adjacent features. Inspired by seismic imaging data processing workflow, we propose the method of source wavelet deconvolution for pre-processing prior to Kirchhoff summation. The idea is to improve the temporal resolution of calibrated raw data by compressing the source wavelet. We also propose the method of picking the first break (arrival) of wave propagation for the purpose of locating the scatterer in the signal. Previously, the signals were integrated prior to Kirchhoff summation, which assumes that a local maximum indicates the round-trip distance between the antenna and the scatterer. In reality, this assumption is not always true due to the complexity of wave propagation (A. Ishimaru, 1997). In this sense, the proposed new processing workflow can be described as improved calibration, skin subtraction, deconvolution, and reconstruction.
Keywords :
image reconstruction; image resolution; medical image processing; microwave imaging; radar imaging; wavelet transforms; Kirchhoff summation; benign inclusions; breast phantoms; calibration; homogeneous breast volume; image focusing; image reconstruction; inclusion location; malignant inclusions; microwave breast imaging; preprocessing; radar-based imaging; scatterer; seismic imaging data processing workflow; skin subtraction; source wavelet deconvolution; spatial resolution; temporal resolution; tomographic reconstruction; wave propagation; Breast; Deconvolution; Image reconstruction; Imaging; Radar imaging; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radio Science Meeting (Joint with AP-S Symposium), 2013 USNC-URSI
Conference_Location :
Lake Buena Vista, FL
Print_ISBN :
978-1-4799-1128-8
Type :
conf
DOI :
10.1109/USNC-URSI.2013.6715514
Filename :
6715514
Link To Document :
بازگشت