DocumentCode :
2942980
Title :
A study on the insulation breakdown of mica-epoxy composites
Author :
Kim, Hee-Gon ; Kim, Hee-Soo ; Park, Yong-Kwan
Author_Institution :
KEPRI, Taejon, South Korea
Volume :
2
fYear :
1997
fDate :
19-22, Oct 1997
Firstpage :
427
Abstract :
Economic factors prevalent at present and for the future mean that the remnant life of machine insulation and its assessment are important factors in the operation and maintenance schemes. In this paper, the chemical structure analysis of mica examined because generator stator winding which is manufactured recently have composed of mica epoxy composites. On components made of mica, a potassium ion of big atomic radius, is replaced by hydrogen ion of small atomic radius. The void created by the difference of these radius and they are progressed by combined stresses. Metal ions such as potassium which can be replaced by hydrogen in metal layers, is formed at the interface parts of mica-mica and mica-epoxy because these conductive layers are progressed with the connection as time goes by. The tree is generated by the effects of localized high electric field which is created in the adjacent areas of conductive layers
Keywords :
chemical structure; composite insulating materials; electric breakdown; epoxy insulation; machine insulation; mica; stators; trees (electrical); chemical structure; generator stator winding; hydrogen ion; insulation breakdown; interface; machine insulation; mica-epoxy composite; potassium ion; remnant life; stress; tree; void; Atomic layer deposition; Atomic measurements; Chemical analysis; Economics; Electric breakdown; Hydrogen; Insulation; Pulp manufacturing; Stator windings; Stress;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1997. IEEE 1997 Annual Report., Conference on
Conference_Location :
Minneapolis, MN
Print_ISBN :
0-7803-3851-0
Type :
conf
DOI :
10.1109/CEIDP.1997.641103
Filename :
641103
Link To Document :
بازگشت