Abstract
In PPPL´s campaign to improve operating efficiency and reduce operating costs of our large vertical shaft motor generators proved to be a fruitful area. The measured losses in the stator air cooling loop were in the area of one megawatt. Reducing these losses was the focus of a recent study by PPPL and GE Hydro. Operating data was used to calculate the load cycle temperature profile of the motor generator. Based on the wide margin between design limitation and operating profile, the estimated energy saving is about 200 KW per hour. An optimum air velocity through the generator stator cooler was determined and means were developed to reduce the flow without compromising generator insulation limits
Keywords
costing; economics; fusion reactor design; fusion reactor operation; pulse generators; TFTR pulse generator; design limitation; energy saving; flow reduction; fusion reactors; generator insulation limits; load cycle temperature profile; operating costs reduction; operating efficiency improvement; operating profile; optimum air velocity; stator air cooling loop; vertical shaft motor generators; windage loss reduction; Cooling; Costs; Friction; Fusion power generation; Loss measurement; Plasma measurements; Pulse generation; Rotors; Shafts; Stators;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1997. 17th IEEE/NPSS Symposium
Conference_Location
San Diego, CA
Print_ISBN
0-7803-4226-7
Type
conf
DOI
10.1109/FUSION.1997.687822
Filename
687822
Link To Document