• DocumentCode
    2943314
  • Title

    Windage loss reduction study for TFTR pulse generator

  • Author

    Awad, M.N. ; Martin, W.J.

  • Author_Institution
    Plasma Phys. Lab., Princeton Univ., NJ, USA
  • Volume
    2
  • fYear
    1997
  • fDate
    6-10 Oct 1997
  • Firstpage
    1125
  • Abstract
    In PPPL´s campaign to improve operating efficiency and reduce operating costs of our large vertical shaft motor generators proved to be a fruitful area. The measured losses in the stator air cooling loop were in the area of one megawatt. Reducing these losses was the focus of a recent study by PPPL and GE Hydro. Operating data was used to calculate the load cycle temperature profile of the motor generator. Based on the wide margin between design limitation and operating profile, the estimated energy saving is about 200 KW per hour. An optimum air velocity through the generator stator cooler was determined and means were developed to reduce the flow without compromising generator insulation limits
  • Keywords
    costing; economics; fusion reactor design; fusion reactor operation; pulse generators; TFTR pulse generator; design limitation; energy saving; flow reduction; fusion reactors; generator insulation limits; load cycle temperature profile; operating costs reduction; operating efficiency improvement; operating profile; optimum air velocity; stator air cooling loop; vertical shaft motor generators; windage loss reduction; Cooling; Costs; Friction; Fusion power generation; Loss measurement; Plasma measurements; Pulse generation; Rotors; Shafts; Stators;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1997. 17th IEEE/NPSS Symposium
  • Conference_Location
    San Diego, CA
  • Print_ISBN
    0-7803-4226-7
  • Type

    conf

  • DOI
    10.1109/FUSION.1997.687822
  • Filename
    687822