DocumentCode
2943761
Title
Calibration of dissipation factor standards
Author
Simmon, E.D. ; FitzPatrick, G.J. ; Petersons, O.
Author_Institution
Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
fYear
1998
fDate
6-10 July 1998
Firstpage
203
Lastpage
204
Abstract
Dissipation factor (DF) standards obtained by connecting a shielded three-terminal capacitor in series with a shielded resistor have been developed for calibration purposes. An analysis of these DF standards, including precautions in their construction and use, is presented and calibration procedures using the NIST high voltage capacitance bridge is discussed.
Keywords
bridge instruments; calibration; capacitors; dielectric loss measurement; measurement standards; NIST high voltage capacitance bridge; calibration; dissipation factor standard; shielded resistor; shielded three terminal capacitor; Admittance; Calibration; Capacitance; Capacitors; Connectors; Joining processes; Measurement standards; NIST; Resistors; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1998 Conference on
Conference_Location
Washington, DC, USA
Print_ISBN
0-7803-5018-9
Type
conf
DOI
10.1109/CPEM.1998.699867
Filename
699867