• DocumentCode
    2943761
  • Title

    Calibration of dissipation factor standards

  • Author

    Simmon, E.D. ; FitzPatrick, G.J. ; Petersons, O.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    203
  • Lastpage
    204
  • Abstract
    Dissipation factor (DF) standards obtained by connecting a shielded three-terminal capacitor in series with a shielded resistor have been developed for calibration purposes. An analysis of these DF standards, including precautions in their construction and use, is presented and calibration procedures using the NIST high voltage capacitance bridge is discussed.
  • Keywords
    bridge instruments; calibration; capacitors; dielectric loss measurement; measurement standards; NIST high voltage capacitance bridge; calibration; dissipation factor standard; shielded resistor; shielded three terminal capacitor; Admittance; Calibration; Capacitance; Capacitors; Connectors; Joining processes; Measurement standards; NIST; Resistors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.699867
  • Filename
    699867