  • Abstract
    The paper deals with the analysis of bypass operation of thyristor converters; in particular the transition from normal to bypass operation and vice-versa is investigated in order to evaluate the maximum current unbalance between the converter subunits, to locate the conditions which zero unbalance corresponds to and to derive the implications on the control system design
  • Keywords
    AC-DC power convertors; Tokamak devices; fusion reactor operation; reactive power control; thyristor convertors; AC/DC converters; ITER; bypass operation; control system design; maximum current unbalance; normal operation; reactive power reduction; thyristor converters; zero unbalance; Bridge circuits; Capacitors; Coils; Control systems; DC-DC power converters; Reactive power; Reactive power control; System analysis and design; Thyristors; Voltage control;