• DocumentCode
    2945578
  • Title

    High-resolution monitoring of air density with an optical wavelength refractometer

  • Author

    Pendrill, L.R. ; Johansson, B. ; Kallgren, H.

  • Author_Institution
    Swedish Nat. Testing & Res. Inst., Boras, Sweden
  • fYear
    1998
  • fDate
    6-10 July 1998
  • Firstpage
    229
  • Lastpage
    230
  • Abstract
    A laser optical wavelength refractometer, based on a Michelson interferometer, is used for gas density determination of air as needed for buoyancy corrections in precision weighings. Comparisons are made with other gas density methods, for example the weighing of sinkers. A laser interferometer with an increased optical path resolution of /spl lambda//400 at 633 nm is employed to monitor density changes at the 10/sup 5/ level.
  • Keywords
    Michelson interferometers; air; density measurement; measurement by laser beam; monitoring; refractometers; 633 nm; Michelson interferometer; air; gas density monitoring; laser optical wavelength refractometer; optical path resolution; Atom optics; Density measurement; Equations; Gas lasers; Laser transitions; Monitoring; Optical interferometry; Optical refraction; Optical variables control; Prototypes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1998 Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-5018-9
  • Type

    conf

  • DOI
    10.1109/CPEM.1998.699881
  • Filename
    699881