DocumentCode :
2947924
Title :
Open Type of Magnetically Shielded Room Combined With Cancelling Coils for Magnetic Resonance Imaging
Author :
Yamazaki, K. ; Hirosato, S. ; Muramatsu, K. ; Hirayama, M. ; Haga, A.
Author_Institution :
Takenaka Corp., Chiba
fYear :
2006
fDate :
8-12 May 2006
Firstpage :
815
Lastpage :
815
Abstract :
In this paper, an open type of MSR combined with cancelling coils is investigated. The optimal position of the cancelling coil from the standpoints of the leakage flux density outside the room and the required current is determined using 3-D magnetic field analysis with the finite element method. Moreover, the structure for maximizing the opening of a MSR is proposed.
Keywords :
biomedical MRI; coils; finite element analysis; magnetic leakage; magnetic shielding; 3-D magnetic field analysis; MRI; coils; finite element method; leakage flux density; magnetic resonance imaging; magnetically shielded room; Bars; Coils; Computed tomography; Finite element methods; Magnetic analysis; Magnetic flux; Magnetic materials; Magnetic resonance imaging; Magnetic shielding; Magnetostatics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Magnetics Conference, 2006. INTERMAG 2006. IEEE International
Conference_Location :
San Diego, CA
Print_ISBN :
1-4244-1479-2
Type :
conf
DOI :
10.1109/INTMAG.2006.374846
Filename :
4262248
Link To Document :
بازگشت